<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>44964</ErrorNumber>
<ErrorFamily>Exposure Head Interface</ErrorFamily>
<ErrorMessage>
EHI: focus error detected at &lt;Subscan location&gt; mm &lt;Relative location&gt; while imaging, check plate for artifacts
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Gravure</Text></ListItem>
<ListItem><Text>Japanese_Newspaper_OEM_Engine</Text></ListItem>
<ListItem><Text>Lotem_Quantum</Text></ListItem>
<ListItem><Text>Magnus_400</Text></ListItem>
<ListItem><Text>Magnus_800</Text></ListItem>
<ListItem><Text>Magnus_VLF</Text></ListItem>
<ListItem><Text>Slave_MCE_Firmware</Text></ListItem>
<ListItem><Text>Thermoflex</Text></ListItem>
<ListItem><Text>Think_Motion_Controller</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
This error indicates that the focus servo detected an error while imaging.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
The imaged plate may or not be considered reject. Inspect the plate
closely for any image artifacts. Dents in the plate will cause this
error to occur. Check for image artifacts around any dents in the plate.
</text></DescriptionText>
<DescriptionText><text>
The position of the first focus error is reported in this error. The
distance is measured from the edge detect side of the plate.
</text></DescriptionText>
<DescriptionText><text>
Call service if this problem persists.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
This error can be caused by large dents in the plate or an improperly
loaded plate.
</Cause>
<Cause>
If the focus system is not setup correctly (ie. head not installed
properly), false focus errors may be reported.
</Cause>
<Parameter>
Subscan location
Subscan location on plate where focus error occurred.
</Parameter>
<Parameter>
Relative location
Relative location on plate where focus error occurred.
</Parameter>
<LastModified>
11-Jul-2002
</LastModified>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../prm/ehi_head_ferrdur.xml</LinkAddress><LinkTitle>PRM: head ferrdur</LinkTitle></Link>
<Link><LinkAddress>../prm/ehi_head_fthresh.xml</LinkAddress><LinkTitle>PRM: head fthresh</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:42 2008 PST
</Updated>
<Links>
</Links>
</Error>